Sceptre Press

Press Releases and Business to Business Portal
Manufacturing

Pill stamp press supplier from SZ-pharma

Pharma clean room supplier in China: Requirements and methods of cleanliness inspection: The number of colonies in the air should be checked after disinfection, before sterile test and during operation to determine whether the aseptic room reaches the specified cleanliness, and there are often settling bacteria and floating bacteria determination methods. Regular revalidation of cleanliness: periodically (every quarter, half a year, one year) or when there is a major change in the clean room facilities, the cleanliness should be re-verified according to the national standard to ensure that the cleanliness meets the requirements, and the original verification records are kept and archived regularly. The verification results were recorded in the aseptic room use register as the original basis of the experimental environment and trend analysis data. Find additional details on tablet press dies.

Air filter refers to the air filter device, which is generally used in clean workshop, clean workshop, laboratory and clean room, or used for dust prevention of electronic machinery communication equipment. There are primary filter, medium efficiency filter, high efficiency filter and sub high efficiency model. Different models have different standards and performance. The comprehensive performance test of clean room includes: Wind speed, air volume (ventilation frequency), temperature and relative humidity, suspended particle number, planktonic bacteria, settling bacteria, static pressure difference, illumination, noise, air flow pattern, self purification time, high-efficiency filter leak detection, total bacterial colonies in the air, total bacterial colonies on the surface of the worktable, total bacterial colonies on the surface of the worktable, total bacterial colonies on the surface of workers’ hands, etc.

V-type mixer series products are high-efficiency asymmetric mixers, which are applicable to the mixing of powder particles with good material fluidity and small physical property differences, as well as the mixing of materials with low mixing degree and short mixing time. Since the flow of materials in the V-type mixing container is stable and will not damage the original shape of materials, the V-type mixer is also applicable to the mixing of granular materials that are easy to break and wear, or fine powder particles, blocks. It is widely used in pharmaceutical, chemical, food and other industries.

What is the Normal Humidity for Clean Rooms? The ideal humidity level for clean rooms depends on various factors, including the type of equipment being used, the materials involved, and the specific application of the clean room. However, a general rule of thumb is that the cleanroom humidity level should be between 40% and 60% relative humidity (RH). This range provides adequate moisture levels to prevent static buildup while preventing excessive condensation that could lead to mold growth or damage to equipment.

Mainly control the pollution of air dust particles and organisms (bacteria) to working objects, and maintain a negative pressure with the atmosphere inside. Pharma cleanroom project It is suitable for precision machinery industry, electronics industry, aerospace industry, high-purity chemical industry, atomic energy industry, optomagnetic product industry, LCD, computer hard disk; pharmaceutical industry, hospital, operating room, sterile ward, food, cosmetics, beverage products Animal laboratory, physical and chemical laboratory, blood station, etc. More cases check our cleanroom project page.

For the air outlet equipped with similar diffuser, the air volume can be found out according to the air volume resistance curve of diffuser (factory air volume resistance curve or field measured air volume resistance curve) and the measured diffuser resistance (the difference between the static pressure in the orifice and the indoor pressure). When measuring, use a micro manometer and a fine pitot tube, or use a fine rubber tube to replace the pitot tube, but the plane of the measuring hole must be parallel to the air flow direction. In addition, other methods approved by the professional testing department can also be used.

Airflow is the most important factor in controlling cleanliness and temperature and humidity, and it also has some influence on noise. Therefore, the wind speed measurement is the first step in the clean room test. The purpose of the wind speed measurement is to confirm that the air flow sent by the filter meets the design specifications, and the second is to confirm the uniformity of the air flow. In some occasions, due to site restrictions, the indoor ventilation volume must also be converted by multiplying the wind speed by the outlet area. Find even more info on https://www.sz-pharma.com/.

Tablet punches and dies manufacturer from sz-pharma.com: Today (Suzhou Pharma Machinery Co., Ltd.) will introduce to you, clean room airflow and influencing factors. There are many factors affecting the airflow in the clean room, such as process equipment, personnel, clean room assembly materials, lighting fixtures, etc. At the same time, the distribution point of airflow above the production equipment should also be considered.

A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, Static control is within a certain demand range, and a specially designed room is given. That is to say, no matter how the external air conditions change, the interior can maintain the characteristics of cleanliness, temperature, humidity and pressure that were originally set. The main function of the clean room is to control the cleanliness and temperature and humidity of the atmosphere that the product comes into contact with, so that the product can be produced and manufactured in a good environmental space. We call such a space a clean room.