Sceptre Press

Press Releases and Business to Business Portal
Tools

Flow meter wholesale manufacturer 2024

Quality flow meter measuring devices provider: Radar level meter adopts non-contact measurement, and has the advantages of high measurement accuracy, not affected by process conditions, easy to install and easy to maintain, so it is widely used in offshore oil platforms in recent years. Today, we would like to take you through several actual cases in offshore oil platform to understand the reasons and solutions of the radar level meter’s measurement value jumping. The first case was an oil field where the radar level meter in the left crude tank jumped to full scale several times during production. A sealed metal cover was used to cover the main body of the sensor, and during the test, it was found by connecting the radar level transmitter that the closed metal cover would result in more false signals throughout the measurement range, and the overall noise line would rise. Read even more information at flow instrumentation.

Measuring principle of radar water level meter: The radar level gauge adopts the working mode of transmitting-reflecting-receiving. The electromagnetic wave emitted by the antenna is reflected by the surface of the measured object and then received by the antenna. After measuring the distance from the water surface to the radar antenna, the elevation of the water surface can be calculated according to the elevation of the radar antenna. The radar water level meter adopts pulse wave technology with low power consumption. It can be powered by two-wire 24 VDC, 485 interface output, or can be directly powered by 12 VDC, SDI-12 interface output, with high accuracy and wider application range.

Level Measurement Solutions for Deaerators: With proper level control and instrumentation, every part of the steam generation cycle can be managed for optimal efficiency. Deaerator Functions: The deaerator serves as an “open” type heat exchanger with its primary function being the removal of oxygen and other corrosive gases from the boiler feedwater. This is accomplished using steam, which can give up about 970 Btu per pound, to support the deaeration process as well as preheat boiler feedwater.

Radar level measurement technology symbolizes precision and innovation in industrial level sensing. Its non-contact operation, resilience in challenging environments and ability to handle measurement scenarios have earned it a reputation. Furthermore, with the integration of IIoT capabilities and temperature compensation features radar sensors continue to evolve and make contributions to advancing processes. As automation and digitalization become more widespread across industries, radar level measurement continues to be a technology that ensures efficiency, safety and reliability in their operations. By relying on radar sensors as guardians, industries can confidently navigate the intricacies of level measurement with unwavering precision.

KAIDI level transmitter manufacturer is dedicated in providing complete customized solutions for a wide range of industrial automation process applications – in material level, liquid flow, pressure and temperature. We are constantly developing and innovating, our core vision – “to provide solutions that exceed customers’ expectations. In 2012, the company successfully expanded its operations both locally and internationally, achieving global success and recognition for quality fork type level switch, magnetic level gauge products and services. Find even more information at kaidi86.com. Our Radar Level Meter has a range of up to 150 meters, frequency up to 120GHz and an accuracy of ±1mm, which can cope with various complex measurement conditions.

Thermal interference. During the operation of the thermal power plant, its thermal equipment will generate a lot of heat, causing changes in the surrounding instruments and ambient temperature. This is what we call thermal interference. These disturbances can affect the components of the magnetrol radar level gauge and further create problems such as inaccurate measurements. Light interference, light interference mainly exists in semiconductor components. Many components used to control instruments are made of semiconductor materials whose conductivity changes under the influence of light. This will affect the normal use of the radar level gauge.

Rod antenna: generally used in strong corrosive environments, with weak anti-interference ability and small range; Flare antenna: stronger anti-interference ability, suitable for more complex environments. The larger the bell mouth, the more concentrated the energy, and the larger the measuring range; Parabolic antenna: the focusing effect is stronger than that of the bell mouth, the anti-interference ability is the strongest, and the range is the largest.

So what can be done about these difficulties? Under the condition of strong dust, on the one hand, the radar with high transmitting energy can be selected, on the other hand, the measurement software with continuous measurement algorithm of wave-loss waiting can be selected. When the radar encounters strong dust, it will not misjudge the measurement result even if the radar loses wave for a short time. After entering the state of continuous measurement algorithm, if the reflection wave of real material surface can be recognized within the set waiting time, the correct measurement value of material surface can be obtained. In the past, only a few foreign radars have this function. At present, there are also domestic radars with this function, and the practical application effect is very good.

Working principle: Working principle of radar level gauge: UHF electromagnetic waves are transmitted to the liquid level of the container under test through the cable or antenna. When the electromagnetic wave touches the liquid level and is reflected back, the instrument detects the time difference between the initial wave and the echo, thereby calculating the liquid level height. Select guided wave radar or airborne radar according to the dielectric constant and measurement length of the measured medium.

The influence of dust accumulation on the transmitter head of the radar level meter, due to the large amount of dust in the working condition of the radar level meter, the dust is easy to adhere, and affected by the ambient temperature, the dust is wet and easy to agglomerate, and the dielectric constant will become larger and adhered The transmitter head and the wall of the bell mouth of the radar level meter affect the accuracy and stability of the radar measurement.